OEM V6 Multi Syringe Pump
OEM V6멀티 시린지펌프 Pump Module > Syringe Pump > Multi Channel Pump- 제품설명
-
- OEM Muti syringe pump (2~8 Channel)
- 60mm stroke (24000,48000) resolution
- 25ul~5ml syringe volume
- 3 way Solenoid valve
- 3,4 way Non distrubution Rotary valve
- Maker : KLOEHN / USA
- 연락처
-
경기본사 : 031-790-1907 (내선2)
대전지사 : 042-824-5167
V6 Multi-Channel Syringe Pumps – Norgren Kloehn
•The Multichannel pump is an economical, robust, high throughput liquid dispensing solution for simultaneous pipetting of fluids.
The V6 55 Series Multi-Channel Pump offers the same performance and accuracy as the V6 Syringe Pump in 2 mechanical resolutions
– 12k and 24k. The V6 Multi-Channel Pump is both flexible and versatile and can be customized to suit a variety of system configurations
with the option of using from 2 – 8 syringe channels
•12k and 24k Resolutions
•25µl – 5ml syringes
•Solenoid or Rotary valves available (Distribution, Non-Distribution and Loop in different materials)
•Custom Options Available
•The Multichannel pump is an economical, robust, high throughput liquid dispensing solution for simultaneous pipetting of fluids.
The V6 55 Series Multi-Channel Pump offers the same performance and accuracy as the V6 Syringe Pump in 2 mechanical resolutions
– 12k and 24k. The V6 Multi-Channel Pump is both flexible and versatile and can be customized to suit a variety of system configurations
with the option of using from 2 – 8 syringe channels
•12k and 24k Resolutions
•25µl – 5ml syringes
•Solenoid or Rotary valves available (Distribution, Non-Distribution and Loop in different materials)
•Custom Options Available
Mechanical
• Mounting holes at top and bottom as well as on the face plate
• Resolutions available (24000 and 48000 increments)
• Maximum Speed is 10000 steps / second.
• Syringe sizes: 25ul to 5ml (supplied separately)
• Valve type: 3 Way Solenoid Valve each channel
• PC board: Driver & Control boards (fully functional motor drivers and control electronics)
• Card-edge connector
• Integrated RS232 Integrated power filterInterface
• RS-485 or RS-232 communications
• Data terminal or OEM protocol
• 1200 to 38.4K baud, 8 data bits, 1 stop bit, no parity, half duplex
• Three inputs, three output ports
• Digital voltmeter
• Switched and wired device addressPower
• Operation at 24V (with a maximum power voltage ripple of 720mv peak-to-peak) Power consumption – 80 watts, 11 watts idle.Syringe Pump:
V6 55 Series Multi-Channel Pump
• Mounting holes at top and bottom as well as on the face plate
• Resolutions available (24000 and 48000 increments)
• Maximum Speed is 10000 steps / second.
• Syringe sizes: 25ul to 5ml (supplied separately)
• Valve type: 3 Way Solenoid Valve each channel
• PC board: Driver & Control boards (fully functional motor drivers and control electronics)
• Card-edge connector
• Integrated RS232 Integrated power filterInterface
• RS-485 or RS-232 communications
• Data terminal or OEM protocol
• 1200 to 38.4K baud, 8 data bits, 1 stop bit, no parity, half duplex
• Three inputs, three output ports
• Digital voltmeter
• Switched and wired device addressPower
• Operation at 24V (with a maximum power voltage ripple of 720mv peak-to-peak) Power consumption – 80 watts, 11 watts idle.Syringe Pump:
V6 55 Series Multi-Channel Pump